Category
- Protomotive FAQ
- Services
- Accessories
- Engine Building Tools for Porsche
- DIY (Do it yourself)
- Protomotive Merchandise
- Cars for Sale
- 911 Carrera / 930 Turbo (1978-1989)
- 964 Carrera / Carrera 4 (1989-1994)
- 993 Turbo 993 Carrera (1994-1998)
- 996 Turbo / GT2 / GT3-1 / 996 Carrera / 986 Boxster
- 997 Turbo / GT2 / GT2RS / GT3-2 / 997 Carrera / 987 Boxster
- 991 Turbo / GT2RS / GT3-3 / Carrera / Cayman / GT4 / 718 / 981 Boxster
- 992 Turbo Carrera GT3 GT4
- Panamera (970/971)
- Cayenne (955/957/958/9YA)
- Macan (95B/95B-2)
Looking for Protomotive 997.1 Turbo Datalogging Instructions? Here you go! This will give you the values we’re after to check your tuning. To get started head over to Durametric.com and download the latest Durametric software and install it. Then download this XML file and put it aside to preload the below values vs. entering them in every time. After Duramtric is installed, fire it up and go into actual values.
Select these parameters: (or click RECALL and load in the XML file downloaded above)
- Engine speed
- Engine load
- Ignition Angle
- Camshaft deviation bank 1
- Camshaft deviation bank 2
- Actual Camshaft Angle bank 1
- Actual Camshaft Angle Bank 2
- Nominal Camshaft angle bank 1
- Nominal Camshaft angle bank 2
- Intake Air temp
- Injection time
- Retardation cylinder 1
- Actual throttle plate angle
- Multipl. correction of mixture adaptation
- Multip. correction of mixture adaptation (B)
- Fuel trim mean value bank 1
- Fuel trim mean value bank 2
- Actual lambda value bank 1
- Actual lambda value bank 2
- Pressure ah. of thr. plate fr. press. Sensor
After selecting the parameters click on the options tab and click CLEAR so it’ll start a new datalog with the selected values.
After that, go out and record some idle, drivability and a few 3rd gear 2000->redline runs (kinda like dyno runs, but on the street).
Then, stop and export the log to an *.xls or *.csv file for me to take a look at.
NOTE: If you click SAVE vs. EXPORT, you’ll save only the above parameters, not actually the log. So be sure to click on EXPORT!
To SAVE the parameter list above to your own XML file to auto populate the list later, click SAVE and enter a filename. Then next time you can save time by loading up the parameter list above and not have to search through them.
Need help on a DIY project? Had another shop tune your car and want help? We can help with Protomotive Consulting
NOTE: Protomotive 997.1 Turbo Datalogging Instructions Pricing for Catalogging purposes only. This page is purely informational
If you’re uncomfortable downloading the XML file, or your browser is giving you security warnings, you can create a new text file on your desktop, cut and paste the information below into that file, save it and rename it to something like “durametric me7.8.1 997 Turbo.xml”
Copy between the brackets, but don’t copy the brackets themselves!
{
<?xml version=”1.0″ encoding=”utf-8″?>
<ActualValueSettings>
<ModuleId>ME781T</ModuleId>
<SamplingRate>0</SamplingRate>
<Toolbar>false</Toolbar>
<MultipleGraphs>false</MultipleGraphs>
<MarkerText>Marker</MarkerText>
<SelectedValue>Engine speed</SelectedValue>
<SelectedValue>Engine load</SelectedValue>
<SelectedValue>Intake-air temperature</SelectedValue>
<SelectedValue>Ignition angle</SelectedValue>
<SelectedValue>Injection time</SelectedValue>
<SelectedValue>Camshaft deviation bank 1</SelectedValue>
<SelectedValue>Camshaft deviation bank 2</SelectedValue>
<SelectedValue>Actual camshaft angle bank 1</SelectedValue>
<SelectedValue>Actual camshaft angle bank 2</SelectedValue>
<SelectedValue>Nominal camshaft angle bank 1</SelectedValue>
<SelectedValue>Nominal camshaft angle bank 2</SelectedValue>
<SelectedValue>Retardation cylinder 1</SelectedValue>
<SelectedValue>Actual throttle plate angle</SelectedValue>
<SelectedValue>Fuel trim mean value bank 1</SelectedValue>
<SelectedValue>Multipl. correction of mixture adaptation</SelectedValue>
<SelectedValue>Actual lambda value bank 1</SelectedValue>
<SelectedValue>Fuel trim mean value bank 2</SelectedValue>
<SelectedValue>multip. correction of mixture adaptation (B)</SelectedValue>
<SelectedValue>Actual lambda value bank 2</SelectedValue>
<SelectedValue>Pressure ah. of thr. plate fr. press. sensor</SelectedValue>
</ActualValueSettings>
}